Discussion of Hp(3) calibration with two thermoluminescent dosimeters in the same standard X-ray RQR radiation field |
LI Wenyan, ZHANG Guiying, LIU Lantao, NIU Dongsheng, GUO Zeqin, WANG Zhichao, TUO Hua, WU Heyan, XIA Tingting, CHU Nini, LAI Jichuan, CHEN Jiaojiao |
Radiochemistry Laboratory of Radiation Technology Department, Beijing Prevention and Treatment Hospital of Occupational Disease for Chemical Industry, Beijing 100093 China |
|
|
Abstract Objective To compare Hp(3) calibration with a homemade (A) thermoluminescent dosimeter (TLD) and an imported (B) TLD in a standard X-ray RQR radiation field, to explore the different responses of A and B, and to provide foundation for the calibration of Hp(3). Methods A column mode was selected. Hp(3) calibration was performed using A and B in a standard X-ray RQR radiation field in the Secondary Standard Dosimetry Laboratory, National Institute for Radiological Protection, China Center for Disease Control and Prevention. Angle response, energy response, and linear response were calibrated with RQR4 (60 kV), RQR7 (90 kV), and RQR9 (120 kV), respectively. Results In terms of angle response, the calibration results of A were relatively high, while the calibration results of B were relatively low. In terms of energy response, the calibration results showed a similar pattern to angle response. In terms of linear response, the calibration results of both A and B were satisfactory. Conclusion Both A and B can be used for normal calibration of Hp(3) in a standard X-ray RQR radiation field. However, in actual monitoring, attention should be paid to the energy and angle response values of TLDs.
|
Received: 19 December 2023
|
|
|
|
|
[1] International Commission on Radiation Units and Measurements. ICRU Report No 51. Quantities and units in radiation protection dosimetry[R]. Bethesda: ICRU, 1993. [2] Gualdrini G, Bordy JM, Daures J, et al. Air kerma to Hp(3) conversion coefficients for photons from 10 keV to 10 MeV, calculated in a cylindrical phantom[J]. Radiat Prot Dosimetry, 2013, 154(4): 517-521. [3] Behrens R. Air kerma to Hp(3) conversion coefficients for a new cylinder phantom for photon reference radiation qualities[J]. Radiat Prot Dosimetry, 2012, 151(3): 450-455. [4] O'Connor U, Walsh C, Gallagher A, et al. Occupational radiation dose to eyes from interventional radiology procedures in light of the new eye lens dose limit from the International Commission on Radiological Protection[J]. Br J Radiol, 2015, 88(1049): 20140627. [5] Domienik J, Rusicka D, Szubert W. A study on the dose distributions near the eye lens and the legs. Part 2-Interventional radiology[J]. Radiat Meas, 2013, 51-52: 62-66. [6] Struelens L, Schoonjans W, Schils F, et al. Extremity and eye lens dosimetry for medical staff performing vertebroplasty and kyphoplasty procedures[J]. J Radiol Prot, 2013, 33(3): 635-645. [7] Pirchio R, Sánchez H, Domazet W. Dosimetric studies of the eye lens using a new dosemeter-surveys in interventional radiology departments[J]. Radiat Meas, 2014, 63: 12-17. [8] Urboniene A, Sadzeviciene E, Ziliukas J. Assessment of eye lens doses for workers during interventional radiology procedures[J]. Radiat Prot Dosimetry, 2015, 165(1/4): 299-303. [9] 李文炎, 范瑶华, 黄卓, 等. 介入手术中职业人员眼晶体受照剂量测量方法及剂量水平研究[J]. 中华放射医学与防护杂志,2016,36(4):303-307. Li WY, Fan YH, Huang Z, et al. The measurements of eye lens dose for occupational staff in interventional procedures[J]. Chin J Radiol Med Prot, 2016, 36(4): 303-307. [10] 李文炎, 张贵英, 王志超, 等. 不同标准X射线RQR辐射场刻度眼晶体当量剂量Hp(3)比较研究[J]. 中华放射医学与防护杂志,2020,40(1):42-46. Li WY, Zhang GY, Wang ZC, et al. Research of TLD calibrated in different standard X-ray RQR radiation field in terms of eye lens dose Hp(3)[J]. Chin J Radiol Med Prot, 2020, 40(1): 42-46. [11] 丁艳秋, 郭文, 胡爱英, 等. 眼晶体、指环剂量计的部分剂量学性能实验测试研究[J]. 中国辐射卫生,2021,30(1):1-4,9. Ding YQ, Guo W, Hu AY, et al. Experimental research on partial dosimetric performance for eye lens dosimeter and ring dosimeter[J]. Chin J Radiol Health, 2021, 30(1): 1-4,9. [12] Ahuja SD. A Catalogue of Spectra for the Calibration of Dosemeters, by W. Seelentag, W. Panzer, G. Drexler, L. Platz, and F. Santner[J]. Med Phys, 1982, 9(1): 134-135. [13] 中华人民共和国国家质量监督检验检疫总局, 中国国家标准化管理委员会. GB/T 19629—2005 医用电气设备X射线诊断影像中使用的电离室和(或)半导体探测器剂量计[S]. 北京: 中国标准出版社, 2005. General Administration of Quality Supervision, Inspection and Quarantine of the People’s Republic of China, Standardization Administration of the People’s Republic of China. GB/T 19629—2005 Medical electrical equipment-Dosimeters with ionization chambers and/or semi-conductors as used in X-ray diagnostic imaging[S]. Beijing: Standards Press of China, 2005. [14] IEC 61267: 2005. Medical diagnostic X-ray equipment-Radiation conditions for use in the determination of characteristics[S]. Geneva: IEC, 2005. [15] 中华人民共和国国家质量监督检验检疫总局. JJF 1059.1—2012 测量不确定度评定与表示[S]. 北京: 中国标准出版社, 2013. General Administration of Quality Supervision, Inspection and Quarantine of the People’s Republic of China. JJF 1059.1—2012 Evaluation and expression of uncertainty in measurement[S]. Beijing: Standards Press of China, 2013. [16] 中华人民共和国国家质量监督检验检疫总局, 中国国家标准化管理委员会. GBZ/T 10264—2014 个人和环境监测用热释光剂量测量系统[S]. 北京: 中国标准出版社, 2015. General Administration of Quality Supervision, Inspection and Quarantine of the People’s Republic of China, Standardization Administration of the People’s Republic of China. GBZ/T 10264—2014 Thermoluminescence dosimetry systems for personal and environmental monitoring[S]. Beijing: Standards Press of China, 2015.
|
|
|
|