Influence of storage temperature and storage time on the optically stimulated luminescence characteristics of chip resistors in dose reconstruction for nuclear accident |
WANG Junlin, WU Jianhua, LIU Yang, CHEN Ling |
China Institute of Atomic Energy, Beijing 102413 China |
|
|
Abstract Objective To assess the feasibility of employing chip resistors for retrospective dose reconstruction following nuclear accidents, to examine the effects of storage temperature and storage time on the optically stimulated luminescence (OSL) characteristics of the chip resistors, and to explore measures to mitigate these effects. Methods Chip resistors were analyzed using automated instruments for measuring thermoluminescence and OSL manufactured by Risø in Denmark with various parameters to understand the impact of storage temperature and storage time on OSL signals. Results The OSL signals of chip resistors exhibited exponential attenuation within 10 min after irradiation, and then stabilized (count change < 10%) within 2-7 days of storage. The chip resistors exhibited linear dose responses within 1-3 days of storage after 0.1-2 Gy irradiation. OSL signals diminished as the storage temperature increased. However, preheating at 130 ℃ for 1 min effectively eliminated the differences caused by temperatures between 25 ℃ and 45 ℃. Conclusion The OSL signals of chip resistors are influenced by storage temperature and storage time. When preheated at 130 ℃ for 1 min, chip resistors stored for 1-7 days and at 25-45 ℃ exhibited OSL signal errors of 10% or less. This result emphasizes the importance of preheating for measurements in practical applications, thus providing a scientific approach and a solid foundation for the use of chip resistors in retrospective dose reconstruction.
|
Received: 08 January 2024
|
|
|
|
|
[1] 吕玉民, 韩林, 李杰, 等. 染色体易位分析在回顾性生物剂量重建中的研究进展[J]. 中华放射医学与防护杂志,2021,41(9):705-710. Lv YM, Han L, Li J, et al. Research progress of chromosome translocation analysis in retrospective biological dose reconstruction[J]. Chin J Radiol Med Prot, 2021, 41(9): 705-710. [2] 刘晓明, 程娇, 崔双双, 等. 成像流式细胞术在辐射生物剂量学指标自动分析中的研究进展[J]. 中国辐射卫生,2023,32(1):62-65. Liu XM, Cheng J, Cui SS, et al. Research progress of imaging flow cytometry in automatic analysis of radiation biodosimetric indicators[J]. Chin J Radiol Health, 2023, 32(1): 62-65. [3] 阎长鑫. 指甲EPR剂量重建优化的拟合研究[D]. 北京: 北京协和医学院, 2021. DOI: 10.27648/d.cnki.gzxhu.2021.000774. Yan CX. A fitting study on optimal dose reconstruction of fingernails EPR[D]. Beijing: Peking Union Medical College, 2021. DOI: 10.27648/d.cnki.gzxhu.2021.000774. [4] 屈喜梅, 刘忠超, 张文艺, 等. 基于辐照后指甲电子顺磁共振谱线的剂量重建[J]. 辐射研究与辐射工艺学报,2013,31(2):020205. Qu XM, Liu ZC, Zhang WY, et al. Dose reconstruction based on EPR spectra of irradiated fingernails[J]. J Radiat Res Radiat Process, 2013, 31(2): 020205. [5] 赵修良, 陈斌, 何淑雅, 等. 辐射事故中食盐光致发光特性研究[J]. 核电子学与探测技术,2018,38(4):521-524. Zhao XL, Chen B, He SY, et al. Photoluminescence characteristics of salt in radiation accidents[J]. Nucl Electron Detect Technol, 2018, 38(4): 521-524. [6] 吴建华, 骆志平, 刘阳, 等. 手机玻璃材料的ESR剂量学特性分析[J]. 科技视界, 2022(33): 1-4. DOI: 10.19694/j.cnki.issn2095-2457.2022.33.01. Wu JH, Luo ZP, Liu Y, et al. ESR dosimetry analysis of mobile phone glass materials[J]. Sci Technol Vis, 2022(33): 1-4. DOI: 10.19694/j.cnki.issn2095-2457.2022.33.01. [7] Lee JI, Kim H, Kim JL, et al. Thermoluminescence of chip inductors and resistors in new generation mobile phones for retrospective accident dosimetry[J]. Radiat Meas, 2017, 105: 26-32. [8] Mrozik A, Marczewska B, Bilski P, et al. OSL signal of IC chips from mobile phones for dose assessment in accidental dosimetry[J]. Radiat Meas, 2017, 98: 1-9. [9] 马向捷, 何志坚, 袁继龙, 等. 石英玻璃用于放射治疗剂量测量可行性的初步实验分析[J]. 中国辐射卫生,2023,32(3):230-234,239. Ma XJ, He ZJ, Yuan JL, et al. Preliminary experimental analysis of the feasibility of quartz glass for radiotherapy dosimetry[J]. Chin J Radiol Health, 2023, 32(3): 230-234,239. [10] Trompier F, Burbidge C, Bassinet C, et al. Overview of physical dosimetry methods for triage application integrated in the new European network RENEB[J]. Int J Radiat Biol, 2017, 93(1): 65-74. [11] Bassinet C, Woda C, Bortolin E, et al. Retrospective radiation dosimetry using OSL of electronic components: results of an inter-laboratory comparison[J]. Radiat Meas, 2014, 71: 475-479. [12] 贾育新, 唐强, 麦维基, 等. 辐射事故中常用电子元件光释光特性研究[J]. 中国职业医学,2015,42(3):259-262. Jia YX, Tang Q, Mai WJ, et al. Characteristics of optically stimulated luminescence in some electronic components often used for radiation accidents[J]. China Occup Med, 2015, 42(3): 259-262. [13] 潘秋秋, 黄丽华, 冯丫娟, 等. 光致光与热释光剂量计部分性能比较[J]. 中国辐射卫生,2019,28(3):318-320. Pan QQ, Huang LH, Feng YJ, et al. The comparison of partial performance between OSL dosemeter and TLD dosemeter[J]. Chin J Radiol Health, 2019, 28(3): 318-320. [14] Lee JI, Chang I, Pradhan AS, et al. On the use of new generation mobile phone (smart phone) for retrospective accident dosimetry[J]. Radiat Phys Chem, 2015, 116: 151-154. [15] Smith RW, Eakins JS, Hager LG, et al. Development of a retrospective/fortuitous accident dosimetry service based on OSL of mobile phones[J]. Radiat Prot Dosim, 2015, 164(1/2): 89-92.
|
|
|
|